Results of soil and groundwater surveys at the business site
April 16, 2008
SEKISUI CHEMICAL Group considers it a corporate social responsibility to reduce the environmental impact associated with business activities and fulfill its role in environmental conservation and creating a comfortable environment, and voluntarily undertakes initiatives to reduce environmental impact and risks associated with business activities and production. As part of these voluntary activities, we systematically conduct surveys of soil and groundwater conditions targeting businesses that have previously or currently handled chemicals designated under the Soil Contamination Control Act. We are pleased to announce that we have conducted a survey of Shikoku Sekisui Industry Co., Ltd.
1. Overview of Shikoku Sekisui Co., Ltd.
1) Address: 880 Himi Otsu, Saijo City, Ehime Prefecture
2) Main products
Since its establishment in 1964, the company has been producing plastic molded products such as containers, PVC pipes and other PVC products, and polyethylene foam products.
3) Investigated substances and their usage history
The substances investigated were those with a history of use among the chemical substances designated under the Soil Contamination Countermeasures Act. The investigated substances and their usage history are shown in the table below.
| Substances under investigation | Purpose | amount | Period |
|---|---|---|---|
| benzene | impurities in gasoline | Gasoline consumption: 4.6 KL/year | 1964 - Present |
| (Forklift fuel) | Diesel fuel 22 KL/year | ||
| lead | Additives for PVC resin (powdered) | 14 tons/year | 1964 - Present |
| Cadmium compounds | Container coloring agent (powder) | 500kg/year | 1964-1981 |
2. Survey Methods and Survey Results
1) Survey Method: The survey was conducted by a specialized survey company in accordance with the Land Contamination Countermeasures Act.
2) Survey Results
(1) soil
① Benzene, cadmium:
No values were found to exceed the specified standard at any of the survey locations.
②Lead:
Exceeding the designated standard values was confirmed in five areas (17 locations) within the site. Furthermore, the depths where the designated standard values were exceeded were less than 1 meter, with the exception of two survey locations. (See attached table and appendix for details)
(2) Groundwater
① Cadmium and 11 types of legally designated organic solvents (including benzene):
No values were found to exceed the specified standard at any of the survey locations.
②Lead:
Water quality was measured three times. As a result, only in May 2007, when the groundwater level had dropped, did the groundwater slightly exceed the designated standard value at two locations on the site. However, in two other measurements conducted at different times (three locations exceeding the designated standard value), no lead was detected at any location (below the limit of quantification), and the designated standard value was satisfied (see table below). Furthermore, in March 2008, analysis of well water from a nearby well downstream of the groundwater flow also did not detect any lead.
| Survey location | Sampling period | |||
|---|---|---|---|---|
| December 2006 | May 2007 | July 16, 2007 | July 31, 2007 | |
| North side of the site | Below the lower limit of quantification | 0.025 mg/L | Below the lower limit of quantification | Below the lower limit of quantification |
| Southwest side of the property | Below the lower limit of quantification | 0.012 mg/L | Below the lower limit of quantification | Below the lower limit of quantification |
Designated reference value: 0.01 mg/L; Lower limit of quantification: 0.005 mg/L
3. Causes of exceeding the designated lead limit
1) Soil
The reason for exceeding the designated standard value is believed to be the gradual accumulation of waste mixed in during the construction of the building in 1989, or from the scattering and spillage of lead compounds used as stabilizers in PVC products.
2) Groundwater
This is considered a temporary phenomenon for the following reasons.
(1) Looking at the rainfall over the past six years, there have been unprecedented droughts.
(Rainfall was as low as in 2005 until June 2007)
(2) The amount of groundwater in May 2007 was lower than during the other two measurements.
(The groundwater level in the northern well has fallen by up to 1.2m compared to December 2006.)
(3) The results from May 2007, when the groundwater level was low, are clearly different from the results from the other two measurements, when the groundwater level was high, and no lead was detected in the latter measurements.
4. Future Actions
We have reported the investigation results to the relevant administrative bodies and neighbors. Moving forward, we will take the following measures promptly, taking into account the guidance of the administration and the requests of the neighbors, while seeking the understanding and cooperation of all parties involved.
1) About the soil
In areas where the standard values were exceeded, unpaved sections have been covered with waterproof sheets as a temporary measure.
Going forward, soil exceeding the standard levels will be excavated and removed, except in areas where it cannot be removed by excavation under the building, and replaced with clean soil.
2) Regarding groundwater
The reason for the groundwater levels exceeding the designated standards is thought to be a temporary phenomenon caused by a decrease in groundwater volume due to an unusually low groundwater level this year. However, we will monitor the groundwater quality in accordance with the provisions of the law.
3) Regarding waste management
Currently, our facility has achieved zero waste emissions, and in maintaining this, we are sorting waste and recycling it through outsourcing to external companies. Going forward, we will further strengthen these efforts.
4) Handling of lead compounds
Regarding the handling of lead compounds during the receiving, storage, and use stages, we will further strengthen control over dispersion and leakage by taking measures such as changing storage locations and modifying the disposal methods for empty bags to prevent scattering and leakage.
That's all.
(Appendix) Summary of lead investigation results
| Location within the site | Survey items | Survey results | Number of values exceeding the specified threshold | maximum depth | |
|---|---|---|---|---|---|
| Northwest side | Elution amount | Maximum 0.28 mg/L | 5 locations | 4 locations | 1m |
| Content | up to 6,500 mg/kg | 5 locations | 1m | ||
| North side | Elution amount | Maximum 0.016 mg/L | 8 locations | 3 locations | 1m |
| Content | up to 2,100 mg/kg | 7 locations | 2m | ||
| Northeast side | Elution amount | Maximum 0.10 mg/L | two parts | 1 location | 4m |
| Content | up to 4,600 mg/kg | two parts | 3m | ||
| west side | Elution amount | Maximum 0.031 mg/L | 1 location | 1 location | 0.5m |
| (Further investigation results: No detection found) | (0 locations) | ||||
| Content | up to 390 mg/kg | 1 location | 0.05m | ||
| east side | Elution amount | Maximum 0.018 mg/L | 1 location | 1 location | 0.5m |
| (Further investigation results: No detection found) | (0 locations) | ||||
| Content | up to 340 mg/kg | 1 location | 0.05m | ||
| grand total | 17 locations | ||||
Designated standard values: ① Elution amount: 0.01 mg/L ② Content: 150 mg/kg
(Attachment) Areas where lead exceeds the specified standard value

Contact information regarding this matter
<For members of the media>
Sekisui Chemical Co., Ltd.
Public Relations Department TEL: 03-6748-6467
<For those outside of the media>
Shikoku Sekisui Industries Co., Ltd.
Production Management Department, Environmental Safety Section TEL: 0897-57-9111 (Main)
Correction made. (November 2019)